        Xiaoguo Factory annos experientiae habet in commercio educendo. Hoc Hexagon Flange Self Tapping Concrete Anchor Bolt tegit magnitudinum ab M6 ad M16. In constructione, rationabilis torques tensis moderari debet ad vitanda fila detracta et materiam basim laedens. Materiae carbonis et chalybis immaculatae diversis condicionibus temperatae accommodandae, securam et certam institutionem procurantes.

        Mitte Inquisitionem

        depictio producti

        Sequens introductio est ad proprietates mechanicas et ad institutionem parametri Hexagoni Flange Sui Tapping Concretae Anchorae Bolt e Sinis Xiaoguo®.

        1.Recommended institutionem parametri

        Nominal diameter Drill frenum diametri (mm) Altitudinem EXERCITATIO (mm) Minimum crassitudine subiecta (mm) Minimum alvi (mm) Minimum spatio (mm) Aureus instruitur (N·m)
        M6 6.0 45 80 45 60 8-12
        M8 8.0 55 90 50 70 15-20
        M10 10.0 70 110 60 85 30-40
        M12 12.0 90 140 75 100 50-65
        M16 16.0 115 180 95 130 90-110

        Hexagon Flange Self Tapping Concrete Anchor Bolt

        EXERCITATIO methodus: Utilise malleo terebra coniuncta cum duro admixto terebra frenum.

        Requisita purgatio: Utere sentinam aeream vel vacuum mundius, ut saltem 4 tempora sufflaas. Pulvis visibilis intra foveam non debet esse.

        Instrumenta instruitur: Impact clavis vel torques clavis, cum nervum hexagonale.

        2.Installation torques et tensis opus

        Aureus institutionis in range commendatione servanda debet. Aureus insufficiens ducet ad ancoras insufficiens; Nimius torques stamina slippage vel damno locali concreto causare potest.

        Post institutionem, ima superficies capitis flange cum fixa componente contactum esse debet, et Exagonum Flange Ipsum Tapping Concrete Anchor Bolt non debet manu verti.

        3.Environmental et temperatus limitations

        Applicabilis temperatus environmental: chalybeum carbonicum, galvanizatum, membrana: -40°C ad +80°C

        Ferrum immaculatum paulo superius temperaturas usque ad ≤ 120°C sustinere potest.

        Hexagon Flange Self Tapping Concrete Anchor Bolt

        Mon #2 #3
        P 56 48
        s max 0.125 0.125
        s min 0.12 0.12
        e min 0.134 0.134
        k max 0.05 0.055
        k min 0.04 0.044
        dc max 0.166 0.177
        de min 0.154 0.163
        h max 0.016 0.016
        h min 0.01 0.01
        d max 0.086 0.099
        d min 0.0813 0.0938
        d1 0.068 0.078

        Communes Errores et Solutiones

        Haec sunt 4 maxime communia errata, quae verisimillimum est evenire cum Hexagon Flange Installing Self Tapping Concrete anchor Bolt, una cum solutionibus respondentibus.

        1. Diameter exercitii frenum falsa est.

        Facis: terebra frenum 1—2 mm maius diametro quam ancora fulmen adhibebatur. Postquam ancora contorsit, emissa est.

        Ratio: Foraminis nimis magna est, et filum non potest attingere ad interiorem parietem foraminis, inde ad nullum certamen efficax.

        Recto accessu: terebra frenum cum diametro exprimente eadem cum ancora fulmine.

        2.Insufficient foraminis purgatio vel incompleta foraminis purgatio

        Perficiendo: Resistentia valde variat cum拧ting in.

        Ratio: Pulvis intra foveam accumulat, ne filum a confligendo.

        Recta ratio: Post EXERCITATIO, aer flare saltem 4 vicibus usque ad flatum aerem manifesto pulvere immunis est. Vel, vacuo lautus uti potes.

        3. EXERCITATIO profunditas insufficiens est.

        Facis: Ancora fulmen plene constrictum est, sed LABIUM cum fixa componente nondum attingit.

        Ratio: Insufficiens fovea profunditas.

        Rectus accessus: Altitudo foraminis 5—10 mm maior esse debet quam efficax profunditas fulminis ancorae.

        4.Tilt cum tensis

        Euismod: Hexagon Flange Sui Tapping Concrete Anchor Bolt fit DECLINIS postquam Habes in.

        Ratio: frenum terebra perpendicularis non est, vel angulus clavis usus in insertione falsa est.

        Rectus accessus: Exercitium electricum custodi perpendicularem in exercitio subiectam; initio, tene ancoram pro manu tua cum intorto in.